Example Problem:
Calculate Air Pollutant Concentrations Downwind
of Air Stripper of
Contaminated Groundwater
Given: Air Toxic
Emission Rates for Air Stripper of Groundwater proposed for
construction in Kent-Auburn area (
|
Pollutant |
CAS |
Q
(grams/sec) |
Type |
ASIL (micrograms/m3) |
|
Vinyl Chloride |
75-01-4 |
0.05 |
A |
0.012 |
The above ASIL for vinyl chloride was obtained from a
Puget Sound Clean Air Agency web site:
http://www.pscleanair.org/regulated/businesses/regulations.aspx
http://www.pscleanair.org/regulated/reg3/asil.pdf
Stack
Height 20 ft 6.096 meters
Stack
Inside Diameter 2 ft 0.6096 meters
Stack
gas exit velocity 10 ft/sec 3.08 m/sec
Stack
gas temperature 68oF 20oC=293.33oK
Ambient
air temperature 68oF 20oC=293.33oK
Receptor
Height 4.92 ft 1.5 meters
Land
is flat terrain in Kent-Auburn Area (use Rural option)
Building
Height 12 ft 3.658 m
Building
Width 8 ft 2.438
m
Building
Length 16 ft 4.877 m
Distance
between stack base and fence 2 m
Find: Use
SCREEN3 or TSCREEN to find the downwind air pollutant concentrations. Note that the stack is not at the "Good
Engineering Practice" height so there will be plume downwash.
_-______________________________________________________________________________________________________________________________________________________________
*** SCREEN3 MODEL RUN
*** *** VERSION DATED 95250 ***
10/07/07
Vinyl Chloride GroundWater Air Stripper 10/7/07
SIMPLE TERRAIN
INPUTS:
SOURCE TYPE = POINT
EMISSION RATE (G/S) =
.500000E-01
STACK HEIGHT (M) =
6.0960
STK INSIDE DIAM (M) =
.6096
STK EXIT VELOCITY (M/S)= 3.0800
STK GAS EXIT TEMP (K) =
293.3300
AMBIENT AIR TEMP (K) =
293.3300
RECEPTOR HEIGHT (M) =
1.5000
URBAN/RURAL OPTION =
RURAL
BUILDING HEIGHT (M) =
3.6580
MIN HORIZ BLDG DIM (M) = 2.4380
MAX HORIZ BLDG DIM (M) = 4.8770
***************************************
***
SUMMARY OF SCREEN MODEL RESULTS ***
CALCULATION MAX CONC
DIST TO TERRAIN
PROCEDURE (UG/M**3) MAX (M)
HT (M)
--------------
----------- ------- -------
SIMPLE TERRAIN 291.4 11. 0.
BLDG. CAVITY-1 987.8 9. --
(DIST = CAVITY LENGTH)
BLDG. CAVITY-2 527.4 3. --
(DIST = CAVITY LENGTH)
BUOY. FLUX = .000 M**4/S**3; MOM. FLUX = .881 M**4/S**2.
*** FULL
METEOROLOGY ***
**********************************
*** SCREEN
AUTOMATED DISTANCES ***
**********************************
*** TERRAIN
HEIGHT OF 0. M ABOVE STACK BASE USED
FOR FOLLOWING DISTANCES ***
DIST CONC U10M
USTK MIX HT PLUME
SIGMA SIGMA
(M) (UG/M**3 STAB
(M/S) (M/S) (M)
HT (M) Y (M) Z (M)
DWASH
2. .0000 1
1.0 1.0 320.0
11.73 1.02 .74
NO
100. 99.18 6
2.5 2.5
10000.0 8.02 4.12
5.40 Yes HS
200. 72.68 6
1.5 1.5 10000.0 9.85
7.80 6.88 Yes HS
300. 56.21 6
1.5 1.5
10000.0 9.85 11.28
8.23 Yes HS
400. 52.64 6
1.0 1.0
10000.0 10.53 14.69
7.16 NO
500. 48.66 6
1.0 1.0
10000.0 10.53 18.01
8.49 NO
600. 42.93 6
1.0 1.0
10000.0 10.53 21.27
9.77 NO
700. 37.35 6
1.0 1.0
10000.0 10.53 24.49
11.00 NO
800. 32.54 6
1.0 1.0
10000.0 10.53 27.66
12.04 NO
900. 28.54 6
1.0 1.0
10000.0 10.53 30.80
13.04 NO
MAXIMUM 1-HR CONCENTRATION AT OR BEYOND 2. M:
11.
291.4 6 4.0
4.0 10000.0
6.11 .62 2.64
Yes HS
*** CAVITY CALCULATION - 1 *** *** CAVITY CALCULATION - 2 ***
CONC (UG/M**3) =
987.8 CONC (UG/M**3) =
527.4
CRIT WS @10M (M/S) = 3.78
CRIT WS @10M (M/S) = 14.17
CRIT WS @ HS (M/S) = 3.78
CRIT WS @ HS (M/S) = 14.17
DILUTION WS (M/S) =
1.89 DILUTION WS (M/S) =
7.09
CAVITY HT (M) =
6.12 CAVITY HT (M) =
4.69
CAVITY LENGTH (M) =
8.62 CAVITY LENGTH (M) =
3.06
ALONGWIND DIM (M) =
2.44 ALONGWIND DIM (M) =
4.88
Note that the concentrations in cavity exceed those at 11
m downwind.
*** USER SPECIFIED AVERAGING TIMES ***
ESTIMATED MAXIMUM CONCENTRATION FOR 24 HR
AVERAGING TIME:
116.56 (+/- 58.28) UG/M**3
Where is this 24 hr
maximum concentration located?
At x = 11 m or in
the building cavity?
1 hr max conc
= (116.56 ug/m3)/0.4 = 291.4 ug/m3 = conc
at x = ll m
ESTIMATED MAXIMUM CONCENTRATION
FOR ANNUAL AVERAGING TIME:
23.312 (+/- 5.828) UG/M**3
Note ASIL =
0.012 for ug/m3 vinyl
chloride annual average
DIST = DISTANCE FROM THE SOURCE
CONC = MAXIMUM GROUND LEVEL CONCENTRATION
STAB = ATMOSPHERIC STABILITY CLASS (1=A, 2=B,
3=C, 4=D, 5=E, 6=F)
U10M = WIND SPEED AT THE 10-M LEVEL
USTK = WIND SPEED AT STACK HEIGHT
MIX HT = MIXING HEIGHT
PLUME HT=
PLUME CENTERLINE HEIGHT
SIGMA Y =
LATERAL DISPERSION PARAMETER
SIGMA Z =
VERTICAL DISPERSION PARAMETER
DWASH = BUILDING DOWNWASH:
DWASH= MEANS NO CALC MADE (CONC
= 0.0)
DWASH=NO
MEANS NO BUILDING DOWNWASH USED
DWASH=HS MEANS HUBER-SNYDER DOWNWASH USED
DWASH=SS MEANS SCHULMAN-SCIRE DOWNWASH USED
DWASH=NA MEANS DOWNWASH NOT APPLICABLE, X<3*LB
**********************************
*** END OF SCREEN MODEL OUTPUT ***
**********************************