Formwork Design Tables - EXAMPLEWall Forms
WALES (Cont’d)
- For example, if double 2x6 wales are used the spacing between ties that support the wales can be a maximum of 33 in.
- A check of the load capacity of available ties might help in confirming the wale selection.
- If the double 2x6 were used with supporting ties spaced at 33 in., the average tie load would be
33/12 x 36/12 x 600 = 4950 lb
- A tie with a safe working load of 5000 lb should be selected.
- With a tie spacing of 24 in., the necessary tie capacity will be 3600 lb. [ 24/12 x 36/12 x 600 = 3600 lb]